Sandia National Laboratories Results for the 2010 Criticality Accident Dosimetry Exercise, at the CALIBAN Reactor, CEA Valduc France, September 2010

机译:桑迪亚国家实验室2010年9月在CEaG Valduc France的CaLIBaN反应堆进行的2010年临界事故剂量测定结果

获取原文

摘要

This document describes the personal nuclear accident dosimeter (PNAD) used by Sandia National Laboratories (SNL) and presents PNAD dosimetry results obtained during the Nuclear Accident Dosimeter Intercomparison Study held 20- 23 September, 2010, at CEA Valduc, France. SNL PNADs were exposed in two separate irradiations from the CALIBAN reactor. Biases for reported neutron doses ranged from -15% to +0.4% with an average bias of -7.7%. PNADs were also exposed on the back side of phantoms to assess orientation effects.