首页> 美国政府科技报告 >Progress on the Upgrade of the CMS Hadron Calorimeter Front-End Electronics.
【24h】

Progress on the Upgrade of the CMS Hadron Calorimeter Front-End Electronics.

机译:Cms Hadron量热仪前端电子产品升级进展。

获取原文

摘要

We present a scheme to upgrade the CMS HCAL front-end electronics in the second long shutdown to upgrade the LHC (LS2), which is expected to occur around 2018. The HCAL electronics upgrade is required to handle the major instantaneous luminosity increase (up to 5 * 10(sup 34) cm(sup -2) s(sup -1)) and an expected integrated luminosity of (approx)3000 fb(sup -1). A key aspect of the HCAL upgrade is to read out longitudinal segmentation information to improve background rejection, energy resolution, and electron isolation at the L1 trigger. This paper focuses on the requirements for the new electronics and on the proposed solutions. The requirements include increased channel count, additional timing capabilities, and additional redundancy. The electronics are required to operate in a harsh environment and are constrained by the existing infrastructure. The proposed solutions span from chip level to system level. They include the development of a new ASIC ADC, the design and testing of higher speed transmitters to handle the increased data volume, the evaluation and use of circuits from other developments, evaluation of commercial FPGAs, better thermal design, and improvements in the overall readout architecture. We will report on the progress of the designs for these upgraded systems, along with performance requirements and initial design studies.