首页> 美国政府科技报告 >An Improved Impregnated-filter Method for Measuring Low-levelConcentrations of Toluene
【24h】

An Improved Impregnated-filter Method for Measuring Low-levelConcentrations of Toluene

机译:一种改进的浸渍过滤法测定低浓度甲苯浓度

获取原文

摘要

An improved method was developed and validated for measuring low-level concentrations of toluene diisocyanates (TDls) in air. The method is based on OSHA Method 42 for industrial applications. Airborne TDls were trapped on a 25-mm glass-fiber filter impregnated with 50 pg of 1-(2-pyridy1)piperazine. A filter holder was constructed to minimize contamination and losses of the analytes. The derivatized TDls were extracted by immersion of the filter in a small volume of solvent. The analysis was performed with a high performance liquid chromatograph equipped with a fluorescence detector and a CIB base-deactivated silica column. The modified method has a lower limit of quantitation of 0.02 ppb in 15 L of air for both 2,4-toluene diisocyanate (2,4-TDI) and 2,6-toluene diisocyanate (2,6-TDI), which is about a fifteen-fold enhancement over Method 42. The recovery efficiencies and 95% confidence intervals for vapor-spiked filters were 77 {+-} 6 percent for 2,4-TDI and 69 {+-} 10 percent for 2,6-TDI. The precision of replicate analyses was ten percent or better. The method was used to screen flexible polyurethane foam for emissions of unreacted TDls.