首页> 美国政府科技报告 >Updated TRAC analysis of an 80% double-ended cold-leg break for the AP600 design
【24h】

Updated TRAC analysis of an 80% double-ended cold-leg break for the AP600 design

机译:更新了针对ap600设计的80%双端冷腿断裂的TRaC分析

获取原文

摘要

An updated TRAC 80% large-break loss-of-coolant accident (LBLOCA) has been calculated for the Westinghouse AP600 advanced reactor design, The updated calculation incorporates major code error corrections, model corrections, and plant design changes. The 80% break size was calculated by Westinghouse to be the most severe large-break size for the AP600 design. The LBLOCA transient was calculated to 144 s. Peak cladding temperatures (PCTS) were well below the Appendix K limit of 1,478 K (2,200 F), but very near the cladding oxidation temperature of 1,200 K (1,700 F). Transient event times and PCT for the TRAC calculation were in reasonable agreement with those calculated by Westinghouse using their (und W)COBRA/TRAC code. However, there were significant differences in the detailed phenomena calculated by the two codes, particularly during the blowdown phase. The reasons for these differences are still being investigated. Additional break sizes and break locations need to be analyzed to confirm the most severe break postulated by Westinghouse.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文