首页> 美国政府科技报告 >Examination of frit vent from Sixty-Watt Heat Source simulant fueled clad vent set
【24h】

Examination of frit vent from Sixty-Watt Heat Source simulant fueled clad vent set

机译:从六十瓦热源模拟燃料包层通风装置检查玻璃料排气口

获取原文

摘要

The flow rate and the metallurgical condition of a frit vent from a simulant-fueled clad vent set (CVS) that had been hot isostatically pressed (HIP) for the Sixty-Watt Heat Source program were evaluated. The flow rate form the defueled vent cup subassembly was reduced approximately 25% from the original flow rate. No obstructions were found to account for the reduced flow rate. Measurements indicate that the frit vent powder thickness was reduced about 30%. Most likely, the powder was compressed during the HIP operation, which increased the density of the powder layer and thus reduced the flow rate of the assembly. All other observed manufacturing attributes appeared to be normal, but the vent hole activation technique needs further refinement before it is used in applications requiring maximum CVS integrity.