首页> 美国政府科技报告 >Analysis of the Retained Gas Sample (RGS) Extruder Assembly
【24h】

Analysis of the Retained Gas Sample (RGS) Extruder Assembly

机译:保留气体样品(RGs)挤出机组件的分析

获取原文

摘要

In order for the Retained Gas Sample (RGS) Extruder Assembly to be safely used it was determined by the cognizant engineer that analysis was necessary. The use of the finite-element analysis (FEA) progarm COSMOS/M version 1.71 permitted a quick, easy, and detailed stress analysis of the RGS Extruder Assembly. The FEA model is a three dimensional model using the SHELL4T element type. From the results of the FEA, the cognizant engineer determined that the RGS extruder would be rated at 10,000 lbf and load tested to 12,000 lbf. The respective input and output files for the model are EXTR02.GFM and EXTR02.OUT and can be found on the attached tape.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号