This report is a compilation of the characterization data collected from the 104-B-1 Tritium Vault and the 104-B-2 Trillium Laboratory. The characterization activities were organized and implemented to evaluate the radiological status and identify any hazardous materials. The data contained in this report reflects the current conditions and status of the 104-B-1 Tritium Vault and 104-B-2 Tritium Laboratory. This information is intended to be utilized in support of future building decontamination and demolition, to allow for proper disposal of the demolition debris as required by the Washington Administrative Code, WAC 173-303, the Hanford Site Solid Waste Acceptance Criteria, WHC-EP-0063, and the Environmental Restoration Disposal Facility Waste Acceptance Criteria, BHI-00139. Based on the historical information and facility inspections, the only hazardous materials sampling and analysis activities necessary were to identify lead paint and asbestos containing materials (ACM) in the 104-B-1 Tritium Vault and the 104-B-2 Tritium Laboratory. Asbestos samples were obtained from the outer boundary of the roof areas to confirm the presence and type of asbestos containing fibers. Lead paint samples were obtained to confirm the presence and quantity of lead paint on the roof trim, doors and vents.