首页> 美国政府科技报告 >Test of two prototype high-temperature superconducting transmission cables
【24h】

Test of two prototype high-temperature superconducting transmission cables

机译:两种原型高温​​超导传输电缆的试验

获取原文

摘要

Two 500-A class prototype high-temperature superconducting cables have been constructed by Southwire Company and tested at Oak Ridge National Laboratory (ORNL). In the first cable, no insulation was used to separate the individual HTS tapes. In the second cable, Kapton tape was used to insulate the HTS tapes between successive layers for the study of AC loss and current distribution. The cables were tested with both DC and AC currents in liquid nitrogen from 77 to 69 K. Both cables achieved DC critical current, I(sub c) greater than 500 A. A calorimetric technique that measures the cable temperature rise under ac currents was used to measure the ac loss of the cables. The un-insulated cable showed a cryoresistive behavior under the 60 Hz AC currents. The insulated cable started to show measurable loss at current where there was corresponding resistive loss.