Galvanic corrosion study of container materials using zero resistance ammeter

机译:采用零电阻电流表的容器材料电偶腐蚀研究

获取原文

摘要

Galvanic corrosion behavior of A 516 steel separately coupled to six different corrosion-resistant alloys was investigated in an acidic brine (pHa2.70) at 30(degree)C 60(degree)C and 80(degree)C using zero resistance ammeter technique. The corrosion-resistant alloys include Alloys 825, G-3, G-30, C-4 and C-22; and Ti Grade-12, which were coupled to A 516 steel at an anode-to- cathode area ratio of one. The galvanic current and galvanic potential were measured as a function of time at all three temperatures. Optical microscopic examination was also performed on all tested specimens to evaluate the extent of surface degradation due to galvanic coupling. The overall results are presented in this paper.