首页> 美国政府科技报告 >Wire breakage in SLC wire profile monitors
【24h】

Wire breakage in SLC wire profile monitors

机译:sLC线形监视器中的断线

获取原文

摘要

Wire scanning beam profile monitors are used at the Stanford Linear Collider (SLC) for emittance preservation control and beam optics optimization. Twenty such scanners have proven most useful for this purpose and have performed a total of 1.5 million scans in the 4 to 6 years since their installation. Most of the essential scanners are equipped with 20 to 40 (micro) m tungsten wires. SLC bunch intensities and sizes often exceed 2 (times) 10(sup 7) particles/(micro)m(sup 2) (3C/m(sup 2)). The authors believe that this has caused a number of tungsten wire failures that appear at the ends of the wire, near the wire support points, after a few hundred scans are accumulated. Carbon fibers, also widely used at SLAC, have been substituted in several scanners and have performed well. In this paper, the authors present theories for the wire failure mechanism and techniques learned in reducing the failures.