首页> 美国政府科技报告 >Rugged miniaturized mass sensors for use in plutonium conversion processes
【24h】

Rugged miniaturized mass sensors for use in plutonium conversion processes

机译:坚固耐用的小型化传感器,用于钚转换过程

获取原文

摘要

Ionization is produced either through Plasma Desorption, in the case of a solid, using fission fragments from a Cf-252 source; or in the case of a gas, via an electron avalanche from the impact on a microsphere detector of (alpha) particles from a radioactive source. The gaseous compound analysis yielded multiple peaks on parent ion and molecular fragments. In the solid compound analysis, the results indicated that solid-state mass spectrometry will provide important information about the degradation of materials by measured changes in molecular weight.