This report summarizes the results of a project sponsored by Honeywell Corporation (formerly AlliedSignal Inc.) Federal Manufacturing and Technologies/Kansas City (FM and T/KC) and conducted jointly with the University of Missouri, Rolla, titled 'Ultrasonic Imaging for Poling Uniformity Measurements in PZT Ceramic Elements.' In this three-month research project, a series of experiments was performed on soft and hard lead-zirconate-titanate (PZT) structures to determine the effectiveness of ultrasonic measurements as a nondestructive method of evaluating poling quality and uniformity. The study revealed that acoustic velocity correlates well with the degree of poling of PZT structures, as predicted by elastic theory. Additionally, time-of-flight (TOF) imaging was shown to be an ideal tool for viewing the spatial distribution of poled material and of material affected by the electric field beyond the edge of electroded regions. Finally, the effectiveness of ultrasonic methods for flaw detection and evaluation of PZT/stainless steel bonds was also demonstrated.