首页> 美国政府科技报告 >Preliminary Study on Acoustic Detection of Faults Experienced by a High-Bypass Turbofan Engine.
【24h】

Preliminary Study on Acoustic Detection of Faults Experienced by a High-Bypass Turbofan Engine.

机译:高旁通涡扇发动机故障声学检测的初步研究。

获取原文

摘要

The vehicle integrated propulsion research (VIPR) effort conducted by NASA and several partners provided an unparalleled opportunity to test a relatively low TRL concept regarding the use of far field acoustics to identify faults occurring in a high bypass turbofan engine. Though VIPR Phase II ground based aircraft installed engine testing wherein a multitude of research sensors and methods were evaluated, an array of acoustic microphones was used to determine the viability of such an array to detect failures occurring in a commercially representative high bypass turbofan engine. The failures introduced during VIPR testing included commanding the engine's low pressure compressor (LPC) exit and high pressure compressor (HPC) 14th stage bleed values abruptly to their failsafe positions during steady state.