This memo is to assess the TFMC test results and compare it with the strand performance. The TFMC is not an ideal object for studying performance of the CICC in a sense that the instrumentation priority was considered secondary to reliability and therefore a lot of assumptions and modeling need to be made to make the comparison against the LMI strand possible. To compare the CICC performance to strand we need to know at least current in the strands, magnetic field and electric field distribution along the strands, temperature profile and strain distribution. In the TFMC we have much less uniform magnetic field and less determined temperature than in the CSMC Inserts, so role of modeling is greater.