首页> 美国政府科技报告 >NOx Control for Utility Boiler OTR Compliance, (Final Report)
【24h】

NOx Control for Utility Boiler OTR Compliance, (Final Report)

机译:电站锅炉OTR合规性的NOx控制,(最终报告)

获取原文

摘要

The objective of the program was to achieve a NOx level below 0.15 lb/106 Btu (with ammonia slip of less than 5 ppm) in the CEDF using PRB coal and B&Ws DRB-4Z low-NOx pulverized coal (PC) burner in combination with dual zone overfire air ports and Fuel Techs NOxOUT System. Commercial installations of B&Ws low-NOx burner, in combination with overfire air ports using PRB coal, have demonstrated a NOx level of 0.15 to 0.2 lb/106 Btu under staged combustion conditions. The proposed goal of the combustion system (no SNCR) for this project is a NOx level at 0.15 lb/106 Btu. The NOx reduction goal for SNCR is 25% from the low-NOx combustion emission levels. Therefore, overall NOx emissions would approach a level of 0.11 lb/106 Btu in commercial installation.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号