The primary purpose of this investigation was to increase the basic knowledge of nucleate and film boiling heat transfer to fluids up to their critical pressures.nThe apparatus incorporated a stainless steel system for containing the fluid. Ten-mil-diameter cylindrical and 1/8-in.-high vertical-plate platinum test sections were placed in the fluid inside a pressure vessel, 5 in. in inside diameter and 21 in. high. The pressure and temperature of the fluid environment were controlled by constant-volume heating of the fluid in the pressure vessel with the aid of seven zones of radiant guard heaters located between the external wall of the pressure vessel and the in¬sulation. Each of these zones was controlled by a differential-thermocouple-sensed circuit that automatically kept the pressure vessel at a prescribed uniform temperature.