This test is identical to the original except that it authorizes the performance of a trial reduction in reactor flow during a prior reactor shutdown. This trial flow reduction will be performed in the same manner as proposed for the actual test, with one exception. This is, that based upon the results of this preliminary test some changes in the timing of the different steps may be indicated. Such changes can readily be handled by making each step dependent upon the observed reactor outlet temperature during the test performance. The other significant change in the production test is the increase in the allowable bulk outlet temperature from Ti + 40 (plus minus) 3(degrees)C(sup *). This change is needed to obtain a reasonable extrapolation of the results of tests No. 1 and No.2 to 90(degrees)C, and is justified from a hazards standpoint by the excellent flow control achieved during test No. 1 and by the trial test that will be run prior to the performance of the actual test No. 2. Other aspects of the test basis and justification are presented in the original production test.