首页> 美国政府科技报告 >Results of production test IP-528-I, Supplement A: B and D Reactors' high tank drawdown test
【24h】

Results of production test IP-528-I, Supplement A: B and D Reactors' high tank drawdown test

机译:生产测试结果Ip-528-I,补充a:B和D反应堆的高罐压降测试

获取原文

摘要

Recent high tank drawdown data obtained at F reactor during periodic high velocity flushes indicated a reduction in flow to the reactor due to building of corrosion products in the high tank discharge lines. The apparent flow reduction at F reactor was verified by conducting a high tank drawdown test. Visual inspection of B, D, and F high tank discharge lines revealed comparable densities of corrosion product buildup, and high tank drawdown data during high velocity flushes at B and D also indicated a reduction in flow. High tank flow rate to the reactor under simulated emergency conditions needed to be accurately determined to establish current backup adequacy. This report presents the results of the tests which were conducted at D reactor on January 20, 1963 and at B reactor on February 11, 1963.