首页> 美国政府科技报告 >Increased coolant flow H Reactor: PITA IP-27-I, Part 1. Supplement A
【24h】

Increased coolant flow H Reactor: PITA IP-27-I, Part 1. Supplement A

机译:增加冷却剂流量H反应器:pITa Ip-27-I,第1部分。补充a.

获取原文

摘要

Purpose of this supplement is to increase the maximum allowable liquid level in the near downcomer for single downcomer operation. The required clearance between the downcomer lid and liquid level is reduced from 24 inches to 18 inches in the near downcomer, providing bulk outlet temperature is maintained less than 93 C.