首页> 美国政府科技报告 >Preliminary Design Study of Removable Integral Steam Generator Units of the Multiple Helically Wound Tube Type for a 1250 MW(TH) H.T.G.C. Reactor
【24h】

Preliminary Design Study of Removable Integral Steam Generator Units of the Multiple Helically Wound Tube Type for a 1250 MW(TH) H.T.G.C. Reactor

机译:1250 mW(TH)H.T.G.C.多螺旋缠绕管式可拆卸整体式蒸汽发生器装置的初步设计研究反应堆

获取原文

摘要

The possibilities of designing a multiple steam generator for a 1250 MW(th) High Temperature Gas-Cooled Reactor, consisting of 18 units which are able to pass through 5 ft diam. holes in the integral prestressed concrete pressure vessel are investigated. A lay-out and design with bundles of multi-start helical tubes is evolved, particular attention being paid to the questions of tube blanking and removal of the unit, and of selection of materials for superheater and reheater tubes. Thermal and stress calculations have been carried out, using the Waagner-Biro Computer Code ADURHELIX. (Atomindex citation 10:488089)