首页> 美国政府科技报告 >ORCENT: A DIGITAL COMPUTER PROGRAM FOR SATURATED AND LOW SUPERHEAT STEAM TURBINE CYCLE ANALYSIS
【24h】

ORCENT: A DIGITAL COMPUTER PROGRAM FOR SATURATED AND LOW SUPERHEAT STEAM TURBINE CYCLE ANALYSIS

机译:ORCENT:用于饱和和低过热蒸汽轮机循环分析的数字计算机程序

获取原文

摘要

The program will perform full-load, design point calculations for steam turbine cycles supplied with throttle steam characteristic of contemporary water reactor power plants and will handle both condensing and back-pressure turbine exhaust arrangements. Turbine performance calculations are based on the General Electric Company method for large steam turbine-generators operating with saturated and low superheat throttle steam. Output includes all information normally shown on a turbine cycle heat balance diagram. The program is written in Fortran IV for the IBM 360/75 computer at Oak Ridge National Laboratory.