首页> 美国政府科技报告 >Analysis of the Savannah River Reactor Emergency Core Cooling System
【24h】

Analysis of the Savannah River Reactor Emergency Core Cooling System

机译:萨凡纳河反应堆应急堆芯冷却系统分析

获取原文

摘要

This report presents a detailed analysis of the heat removal capability of the Savannah River reactor emergency core cooling system. The capability of the system is evaluated in terms of its ability to cope with a loss-of-coolant accident or a loss-of-circulation accident. In addition to analyses of the present system design, several possible system improvements have been evaluated. The consequences and likelihood were considered of a rupture in any of the cooling systems of SRP reactors, i.e., the D sub 2 O primary, H sub 2 O secondary, and H sub 2 O emergency cooling systems. Accidents covering a wide range of leak rates were analyzed rather than selecting only the worst conceivable accident, because the degree of protection afforded varies with the leak rates. The emergency core cooling system was analyzed in two modes of operation: (1) all equipment operating as designed and (2) failure of that active component causing the most serious consequences. Calculations apply to emergency cooling of the reactor core design having, under most conditions, the most difficult cooling requirements of any core now in use at Savannah River. (ERA citation 09:022564)