首页> 美国政府科技报告 >Preliminary evaluation of the gaseous effluent sampling system at the 296-S-18 stack, 242-S evaporator
【24h】

Preliminary evaluation of the gaseous effluent sampling system at the 296-S-18 stack, 242-S evaporator

机译:初步评估296-s-18烟囱242-s蒸发器的气态流出物取样系统

获取原文

摘要

This evaluation of the 296-S-18 stack sampling system is part of a larger study, sponsored by ARHCO and conducted by Battelle-Northwest, of gaseous effluent sampling systems in ARHCO facilities. It is the fourth and last in a series of evaluations of tank farm stack sampling systems. The objectives of this study are: Evaluate the compliance of the existing effluent particulate sampling system with ARHCO's Interim Criteria for such systems by using sampling theory and radioactivity counting statistics; and make recommendations for corrective action which will lead to a particulate sampling system in compliance with the Interim Criteria. This study is considered preliminary because no experiments have been conducted to verify the sampling system's performance. The following report includes a brief summary, a detailed description and evaluation of the sampling system, conclusions about satisfactory or deficient areas of the sampling system and recommendations for corrective action. The appendices contain a copy of the Interim Criteria and the applicable ARHCO Emergency Procedure for radioactive gaseous discharges.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号