首页> 美国政府科技报告 >Criticality Safety Survey Computations of Uranium Hexafluoride Freezer/Sublimer Tube Lattices
【24h】

Criticality Safety Survey Computations of Uranium Hexafluoride Freezer/Sublimer Tube Lattices

机译:六氟化铀冷冻/升华管格子的临界安全调查计算

获取原文

摘要

The ANISN computer code has been used at the Oak Ridge Gaseous Diffusion Plant to survey the nuclear properties of infinite UF sub 6 freezer/sublimer tube lattices immersed in hydrogen fluoride-moderated UF sub 6 over the 1.0 to 5.0% exp 235 U enrichment range. Refrigerant-114 (R-114) at various densities was present with each freezer/sublimer tube. Infinite-medium multiplication factors were also determined for homogeneous UF sub 6 /HF and UF sub 6 /R-114 systems. The survey provides a broad overview of the nuclear properties of UF sub 6 freezer/sublimers and guidance for future computations on specific designs of these units proposed for gaseous diffusion plant application at a maximum exp 235 U enrichment of 5%. (ERA citation 02:057272)

著录项

  • 作者

    Taylor, R. G.;

  • 作者单位
  • 年度 1977
  • 页码 1-27
  • 总页数 27
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 工业技术;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号