The Fermilab 500-GeV main accelerating system has been operating for a year now with the aid of 128-MHz mode dampers. Such dampers proved to be necessary to achieve stable operation and a reasonably smooth slow spill at intensities of approximately 2 x 10 exp 13 protons per pulse, and furthermore are low-cost and reliable. The approach used to identify troublesome modes, the observed beam blow-up without dampers, and the steps taken to design and install suitable dampers on eighteen main ring cavities are discussed. Spectrum analyzer pictures help illustrate the performance. (ERA citation 02:049454)