首页> 美国政府科技报告 >Central Receiver Solar Thermal Power System, Phase 1. CDRL Item 2. Pilot Plant Preliminary Design Report. Volume VI. Electrical Power Generation and Master Control Subsystems and Balance of Plant
【24h】

Central Receiver Solar Thermal Power System, Phase 1. CDRL Item 2. Pilot Plant Preliminary Design Report. Volume VI. Electrical Power Generation and Master Control Subsystems and Balance of Plant

机译:中央接收器太阳能热电系统,第1阶段.CDRL项目2.试验工厂初步设计报告。第六卷。发电与主控制子系统及工厂平衡

获取原文

摘要

The requirements, performance, and subsystem configuration for both the Commercial and Pilot Plant electrical power generation subsystems (EPGS) and balance of plants are presented. The EPGS for both the Commercial Plant and Pilot Plant make use of conventional, proven equipment consistent with good power plant design practices in order to minimize risk and maximize reliability. The basic EPGS cycle selected is a regenerative cycle that uses a single automatic admission, condensing, tandem-compound double-flow turbine. Specifications, performance data, drawings, and schematics are included. (ERA citation 03:054841)