LOFT Primary Coolant Addition and Control Piping System Stress Analysis

机译:LOFT主冷却剂添加和控制管道系统应力分析

获取原文

摘要

A stress analysis was performed on the Primary Coolant Addition and Control Piping System to determine if it met the conditions of the ASME Code, Section III, for Class 2 components. Results indicate that the Addition and Control System does not meet Section III criteria as the system is now installed. Only hanger (support) modifications are required to bring the stresses within the limits set forth in the Code. A design temperature of 459 exp 0 F was assumed for the analysis. The specified design temperature of 650 exp 0 F has been revised by ECRA's L-5713 and L-5714. (ERA citation 04:046604)