首页> 美国政府科技报告 >Critical Heat Flux Tests of a Simulated Power Burst Facility Rod Bundle
【24h】

Critical Heat Flux Tests of a Simulated Power Burst Facility Rod Bundle

机译:模拟电源突发装置杆束的临界热通量测试

获取原文

摘要

Critical heat flux (CHF) tests were performed at low pressure in a close-packed rod bundle. The test bundle was electrically heated with geometrical configurations the same as the Power Burst Facility nuclear core. Existing low pressure CHF correlations, namely Bernath's and Lund's, did not correlate the test data well. The Bernath correlation overpredicts CHF in some cases by a factor of five when compared with measured values. Lund's correlation overpredicts CHF at measured CHF values above 1.5 MW/m exp 2 , and underpredicts CHF at measured CHF values below 1.5 MW/m exp 2 . These CHF tests provided the first close-packed rod bundle data with a sufficient data base to develop a correlation. The study examined CHF with absolute coolant system pressures of 117 to 255 kPa, mass velocities of 1992 to 4830 kg/s . m exp 2 , and subcooling of up to 53 exp 0 C with a rod spacing of 1.02 mm. (ERA citation 04:003348)