首页> 美国政府科技报告 >Reliability Analysis for the Safety Injection (SI) System of the Doel I - II Power Plant in Case of a LOCA
【24h】

Reliability Analysis for the Safety Injection (SI) System of the Doel I - II Power Plant in Case of a LOCA

机译:基于LOCa的Doel I - II发电厂安全注入(sI)系统可靠性分析

获取原文

摘要

An assement is made for the failure probability of the safety injection system of the Doel power plant. The SI system is composed of three subsystems: high pressure, low pressure and accumulator system. For each subsystem a fault tree is constructed and these fault trees are evaluated by a computer code which calculates the mean system failure probability and the error bounds. (Atomindex citation 10:455340)