首页> 美国政府科技报告 >Measurement of the Supralinearity of exp 7 LiF Thermoluminescent Dosimeters
【24h】

Measurement of the Supralinearity of exp 7 LiF Thermoluminescent Dosimeters

机译:测量exp 7 LiF热释光剂量计的超对称性

获取原文

摘要

A study has been made of the supralinearity of the exp 7 LiF thermoluminesecent dosimeter (T.L.D.) used in the UKAEA personnel criticality dosimeter by exposure to a exp 60 Co source. the response of the T.L.D. was linear up to approximately 450 rad, above which it became increasingly supralinear, over-reading by about 50% at 2000 rad. The results have been used to produce a correction graph, as a function of apparent dose up to 3500 rad, for routine use in nuclear accident dosimetry. (Atomindex citation 09:418990)