首页> 美国政府科技报告 >Critical Separation Between Subcritical Clusters of 4.29 Wt % exp 235 U Enriched UO sub 2 Rods in Water with Fixed Neutron Poisons
【24h】

Critical Separation Between Subcritical Clusters of 4.29 Wt % exp 235 U Enriched UO sub 2 Rods in Water with Fixed Neutron Poisons

机译:4.29 Wt%exp 235 U亚临界团簇在固定中子毒物水中富集UO sub 2棒的临界分离

获取原文

摘要

Measurement data are presented from a series of criticality experiments on systems simulating fuel element shipping containers and fuel storage basins. The conditions investigated involve clusters of 4.29 wt% exp 235 U enriched UO sub 2 fuel rods immersed in water. The number of rods required for criticality in a square lattice spacing (25.4 mm) near optimum neutron moderation and the critical separation between three subcritical clusters aligned in a row was determined. The effect that the following fixed neutron absorbers had on this critical separation was also measured: 304L steel with 0, 1.1, and 1.6 wt% boron; boral; copper with 0 and 1 wt% cadmium; cadmium; aluminum; and zircaloy-4. The fuel rods are 12.649 mm in dia, clad in 0.660 mm thick, 12.827 mm ID aluminum tubing and varied in length from 914 mm to 927 mm. The neutron absorbers are in the form of plates and are positioned between the fuel clusters such that no line of sight existed between the clusters. Measurements were made with each absorber plate located approximately midway between the fuel clusters and with the plates near the respective cell boundary of the center fuel cluster. (ERA citation 03:045149)