首页> 美国政府科技报告 >Ion Beam Measurements of Depth Profiles of Deuterium Concentration in Steels. Pt.1: Investigation of 18Ni250 High Temperature Aged Martensitic Steel
【24h】

Ion Beam Measurements of Depth Profiles of Deuterium Concentration in Steels. Pt.1: Investigation of 18Ni250 High Temperature Aged Martensitic Steel

机译:离子束测量钢中氘浓度的深度剖面。 pt.1:18Ni250高温老化马氏体钢的研究

获取原文

摘要

An ion beam technique has been used to study the concentration of deuterium as a function of depth in 18Ni250 maraged steel. The technique involves the D(D,P)T reaction induced in samples by a deuteron beam, combined with computer analysis of the energy spectrum of the reaction protons. Measurements of concentrations down to 10 weight parts/million have been achieved, following the introduction of the deuterium into samples by cathodic charging. The concentration profiles were found to possess an initial maximum at a depth of about 2 microns. It is inferred that deuterium migrated both into the bulk and to the surface where it escaped, both during and after cathodic charging. (Atomindex citation 14:757595)