Graphite permeability measurements made at AERE in support of the commercial AGR moderator corrosion studies have been made at and below 1 bar pressure. Doubts have been expressed regarding the validity of permeability coefficients, particularly A sub 0 (the turbulent flow coefficient), measured at low pressure when applied to commercial AGR pressures. This paper describes permeability measurements made in a simple apparatus operated at pressures up to 41 bars in carbon dioxide. The results obtained are compared with those derived from the conventional low pressure method. Within a factor of approximately 2, B sub 0 (the viscous flow coefficient) remained constant for all the specimens examined over the whole pressure range of 1 to 41 bars. In all cases, A sub 0 showed a decrease with increasing pressure from 1 to 20 bars but thereafter the coefficient remained effectively constant at pressures up to 41 bars. These figures are similar to those previously reported. (Atomindex citation 11:504912)