首页> 美国政府科技报告 >Tokamak Fusion Test Reactor (TFTR) Neutral Beam Line Vacuum Chamber Cover Structural Analysis
【24h】

Tokamak Fusion Test Reactor (TFTR) Neutral Beam Line Vacuum Chamber Cover Structural Analysis

机译:托卡马克聚变试验反应堆(TFTR)中性束线真空室盖结构分析

获取原文

摘要

The Tokamak Fusion Test Reactor (TFTR) vacuum chamber cover is sealed by 0-rings without the aid of mechanical fasteners. Under vacuum loading and component weights, the edges lifted no more than 0.005 in. (by a SAP4 computer code analysis). This report explains the model used for this investigation and, in addition, shows the maximum deflection expected at the center of the cover is less than 0.047 in. Also, no stresses are expected to exceed 13,700 psi. (ERA citation 05:017271)