首页> 美国政府科技报告 >Debris Bed Heat Removal Models: Boiling and Dryout with Top and Bottom Cooling
【24h】

Debris Bed Heat Removal Models: Boiling and Dryout with Top and Bottom Cooling

机译:碎屑床除热模型:沸腾和干燥,顶部和底部冷却

获取原文

摘要

A one-dimensional deep bed model for incipient dryout is developed which predicts deep bed behavior but not shallow bed behavior. A fluidization criterion results which indicates that a debris bed cannot be fluidized by the vapor flow. However, the maintenance of channels within the bed is predicted. A top-subcooled bed model is presented and evidence (both experimental and calculational) is given that the top-subcooled zone removes heat in series (not in parallel) with the boiling zone for sodium-cooled systems. The Sandia D-2 and D-3 top-subcooled dryout data is expressed in terms of non-subcooled dryout and compared with experimental data and model predictions from the literature. The data agrees with several predictions depending on whether the dryout in the boiling zone is dependent on the overlying subcooled zone thickness. A bottom-subcooled bed model is also presented. A post-dryout model is developed to explain the stable dry zone observed in the D-3 experiment and agreement with the data is found. Finally, the top-subcooled and post-dryout models developed are used to make predictions for the upcoming D-4 experiment. (ERA citation 04:055007)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号