首页> 美国政府科技报告 >Results of Small Break LOCA Experiments in the LOFT Reactor System with Comparison to Code Calculations
【24h】

Results of Small Break LOCA Experiments in the LOFT Reactor System with Comparison to Code Calculations

机译:LOFT反应器系统中小破口LOCa实验的结果与代码计算的比较

获取原文

摘要

The results are presented of three small break loss-of-coolant experiments performed in the LOFT Pressurized Water Reactor (PWR) system. Experiment L3-0, performed without reactor power, represented a loss of coolant from the power operated relief valve on the top of the pressurizer. Experiments L3-1 and L3-2 were initiated with the reactor at full power (maximum linear heat generation rate approximately 52 kW/m) and represented 4-in and 1-in diameter breaks, respectively, in the reactor inlet piping of a commercial PWR. Comparisons of data to analytical model calculations with a number of different models indicate that most major phenomena were correctly calculated, but that improvements in modeling small break behavior are necessary. (ERA citation 05:020658)