首页> 美国政府科技报告 >Investigation of Small Break Loss-of-Coolant Phenomena in a Small Scale Nonnuclear Test Facility
【24h】

Investigation of Small Break Loss-of-Coolant Phenomena in a Small Scale Nonnuclear Test Facility

机译:小型非核试验设施中小断裂冷却损失现象的研究

获取原文

摘要

A small-scale nonnuclear integral test facility designed to simulate a pressurized water reactor (PWR) system was used to evaluate the effects of a small break loss-of-coolant accident (LOCA) on the system thermal-hydraulic response. The experiment approximated a 2.5% (11-cm diameter) communicative break in the cold leg of a PWR, and included initial conditions which were similar to conditions in a PWR operating at full power. The 2.5% break size ensured that the nominal break flow rate was greater than the high pressure injection system (HPIS) flow rate, thus providing the potential for a continuous system depressurization. The sequence of events was similar to that used in evaluation model analysis of small break loss-of-coolant accidents, and included simulated reactor scram and loss of offsite power. Comparisions of experimental data with computer code calculations are used to demonstrate the capabilities and limitations of integral system calculations used to predict phenomena which can be important in the assessment of a small break LOCA in a PWR. (ERA citation 05:038188)