首页> 美国政府科技报告 >District Heating/Cogeneration Application Studies for the Minneapolis-St. Paul Area. Modfifications of the Existing Units at the High Bridge Power Plant to Cogeneration for Hot Water District Heating
【24h】

District Heating/Cogeneration Application Studies for the Minneapolis-St. Paul Area. Modfifications of the Existing Units at the High Bridge Power Plant to Cogeneration for Hot Water District Heating

机译:明尼阿波利斯 - 圣保罗的区域供暖/热电联产应用研究保罗区。高桥电厂现有机组改造为热水区域供热的热电联产

获取原文

摘要

The electrical generating turbines at the High Bridge Generating Station were evaluated for their suitability for conversion to cogeneration. This evaluation required examinations of the equipment, the operating reports, and the technical manuals and drawings. The evaluation also included discussions with the plant staff and with the major vendors of the operating equipment. Units 3, 5, and 6 were recommended for conversion to cogeneration-unit 3 to be converted to back-pressure operation and units 5 and 6 to be converted to condensing-tail operation. Unit 4 was not recommended for conversion. (ERA citation 05:038312)