首页> 美国政府科技报告 >Thermal-Hydraulics of the PFB/LOFT Lead Rod Loss-of-Coolant Experiments
【24h】

Thermal-Hydraulics of the PFB/LOFT Lead Rod Loss-of-Coolant Experiments

机译:pFB / LOFT铅棒冷却剂损失实验的热工水力学

获取原文

摘要

Results of the four PBF/LOFT Lead Rod sequential blowdown tests conducted in the Power Burst Facility (PBF) are presented. The primary objective of the test series was to evaluate the extent of mechanical deformation that would be expected to occur to low pressure (0.1 MPa), light water reactor design fuel rods subjected to a series of nuclear blowdown tests, and to determine if subjecting deformed fuel rods to subsequent testing would result in rod failure. The extent of mechanical deformation (buckling, collapse, or waisting of the cladding) was evaluated by comparison of cladding temperature versus system pressure response with out-of-pile experimental data, and by posttest visual examinations and cladding diametral measurements. Tests LLR-3, LLR-5, LLR-4, and LLR-4A were performed at system conditions of 595 exp 0 K coolant inlet temperature, 15.5 MPa system pressure, and 41, 46, 57 and 56 kW/m test rod peak linear powers, respectively, at initiation of blowdown. Cladding temperatures during the tests ranged from 870 to 1260 exp 0 K. (ERA citation 05:034981)