首页> 美国政府科技报告 >Treatment of Measurement Uncertainties at the Power Burst Facility
【24h】

Treatment of Measurement Uncertainties at the Power Burst Facility

机译:电力突发装置测量不确定度的处理

获取原文

摘要

The treatment of measurement uncertainty at the Power Burst Facility provides a means of improving data integrity as well as meeting standard practice reporting requirements. This is accomplished by performing the uncertainty analysis in two parts, test independent uncertainty analysis and test dependent uncertainty analysis. The test independent uncertainty analysis is performed on instrumentation used repeatedly from one test to the next, and does not have to be repeated for each test except for improved or new types of instruments. A test dependent uncertainty analysis is performed on each test based on the test independent uncertainties modified as required by test specifications, experiment fixture design, and historical performance of instruments on similar tests. The methodology for performing uncertainty analysis based on the National Bureau of Standards method is reviewed with examples applied to nuclear instrumentation. (ERA citation 05:034942)