首页> 美国政府科技报告 >Evaluation of Toledo Edison Company's 316(A) and 316(B) Demonstrations for the Bay Shore Station
【24h】

Evaluation of Toledo Edison Company's 316(A) and 316(B) Demonstrations for the Bay Shore Station

机译:评估托莱多爱迪生公司的316(a)和316(B)湾岸站示范

获取原文

摘要

Toledo Edison Company's Bay Shore steam electric generation station in Oregon, Ohio, discharges effluents into nearby Maumee Bay. Demonstration report 316(a) by WAPORA (1977) analyzed the impacts of thermal discharge on Maumee Bay, and demonstration report 316(b) by Reutter et al (1978) analyzed the impact of entrainment and impingement on fish communities. Pacific Northwest Laboratory assessed these two reports. We generally agree with WAPORA (1977) on the impact of thermal effluents on the Maumee Bay ecosystems. Our computations indicated temperature increases which would result in larger areas of isotherms, but these increases were insignificant in terms of the percent of the area of Maumee Bay affected. We basically agree with Reutter et al (1978) conclusions concerning impingement and entrainment losses at Bay Shore Station. Our calculations indicate that the impingement data presented in Reutter et al (1978) are accurate estimates based on their sampling program. Their 95% confidence limits for less frequently caught species of fish, however, are too conservative. (ERA citation 06:017524)

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号