This report covers the analysis of a failure which occurred during static testing of a Type III Lock Hopper Valve P/N 75835. The unit was assembled and acceptance tested at Consolidated Controls Corporation and static tested at the Morgantown Energy Technology Center. After testing at 850 exp 0 F, the internal leak rate had increased to an unacceptable level. The leakage is felt to be caused by damage to the cast refractory lining used in the valve. (ERA citation 06:019639)