Losses have been measured on a prototype conductor for the 20 MJ coil for conditions which simulate closely the actual coil field sweep. The data on the prototype II conductor indicates coil losses which exceed the coil specification. The application of certain correction factors reduces the projected losses within the specification for a 2 s reversal but not for a 1 s reversal. Verification of these corrections await measurements on the actual strand and completion of coil construction and testing. (ERA citation 07:017061)