首页> 美国政府科技报告 >Two-Phase Natural-Circulation Experiments in a Test Facility Modeled after Three Mile Island Unit-2. Final Report
【24h】

Two-Phase Natural-Circulation Experiments in a Test Facility Modeled after Three Mile Island Unit-2. Final Report

机译:在三里岛二号机组模拟的测试设施中进行两阶段自然循环实验。总结报告

获取原文

摘要

A series of natural circulation experiments was conducted in a test facility that was configured after the primary and the secondary cooling systems of TMI-2. Results support the feasibility of core residual heat removal by two-phase natural circulation. Tests with noncondensable gas in the primary system indicate that two-phase natural circulation is quite tolerant of the presence of noncondensable gas. The different modes of natural circulation were discovered. Mode 1, during which only saturated steam flows in the hot leg, accomplishes the heat removal via phase changes in the vessel and in the steam generator tubes. Mode 2, during which a percolating flow exists in the hot leg, removes the heat by means of a much faster circulation in the primary loop. (ERA citation 07:004272)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号