首页> 美国政府科技报告 >Coefficient of Thermal Expansion of Fluorinert as a Function of Volume Percent Absorbed Air
【24h】

Coefficient of Thermal Expansion of Fluorinert as a Function of Volume Percent Absorbed Air

机译:作为体积百分比吸收空气的函数的氟化物热膨胀系数

获取原文

摘要

The relationship between the coefficient of volumetric thermal expansion of liquid Fluorinert FC-86 and the volume percent of absorbed air was examined experimentally. A special test apparatus was built for this purpose. A floating liquid seal was used to isolate the Fluorinert sample from the atmosphere. This prevented gas absorption during thermal cycling yet allowed the sample to expand and contract freely during testing. It was found that the coefficient of thermal expansion is not influenced by the percentage of absorbed air. (ERA citation 07:057473)