首页> 美国政府科技报告 >Results of the Walnut Creek House-Doctor Project
【24h】

Results of the Walnut Creek House-Doctor Project

机译:Walnut Creek House-Doctor项目的结果

获取原文

摘要

The results of an experiment designed to measure the additional energy savings achieved by adding two person-days of house doctoring to a standard energy audit. A house doctor and audit treatment is compared to an audit alone and to a passive control group. The results of a fourth treatment, house doctoring, audit and contractor retrofits, have not yet been analyzed. The treatments were applied to randomly selected groups of 10 houses each in Walnut Creek, California. The difference in energy savings between the treatments, based on monthly utility bills, was not statistically significant due to wide variation in savings and the loss of several houses from each group. Predicted energy savings, based in part on measured air leakage area reductions, indicated that the retrofit package completed during house doctoring had a Cost of Conserved Energy of 42 cents/therm. (ERA citation 08:010092)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号