首页> 美国政府科技报告 >Flow-Induced Vibration Characteristics of BWR/6-238 Jet Pumps
【24h】

Flow-Induced Vibration Characteristics of BWR/6-238 Jet Pumps

机译:BWR / 6-238射流泵的流体诱导振动特性

获取原文

摘要

Four prototype BWR/6-238 jet pumps (two jet pump pairs) were tested to determine their flow-induced vibration (FIV) characteristics in the High Flow Hydraulic Facility, (HF) exp 2 , over the period June to September 1978. Tests consisted of operating the jet pumps, which were heavily instrumented with accelerometers, pressure transducers and strain gages, at the design operating condition, as well as at numerous off-design drive flows and M-ratios, and at temperatures between 70 exp 0 F and 180 exp 0 F and at 455 psig. Results were combined with those from past jet pump tests to predict the response at reactor temperature (533 exp 0 F). Major conclusions reached related to the BWR/6-238 jet pump are presented. (ERA citation 08:007456)