首页> 美国政府科技报告 >Determination of Trace Impurities in Sulfur Hexafluoride Gas by Thermal Conductivity and Flame Photometry in Series
【24h】

Determination of Trace Impurities in Sulfur Hexafluoride Gas by Thermal Conductivity and Flame Photometry in Series

机译:- 导热系数火焰光度法测定六氟化硫气体中痕量杂质

获取原文

摘要

Relative errors for SO sub 2 F sub 2 determination are less than 10% and that repetition is very good. For the determination of SOF sub 2 , the relative error is comparatively higher but usually less than 30%. This is because the content of SOF sub 2 is very low, and the correction factor is only 0.08. These experiments prove that by using a method consisting of thermal conductivity and flame photometry in series to measure sulphur fluoride, reliable test results can be obtained. When 2 ml samples are injected, the lowest detectable concentrations are: SO sub 2 F sub 2 5 ppM; SOF sub 2 0.5 ppM, much better than present documented values. Because the sulphur in SF sub 6 and sulphur fluoride is comparatively stable, it is difficult to reduce it in the hydrogen-rich flame of the flame photometric detector (FPD). The sensitivity of the FPD is therefore lower than that for measuring most sulphur-containing organic material, moreover the slopes of the calibration graphs are also lower (only about 1.5) than the theoretical value (=2); because of this, before measuring, the FPD must be adjusted to its most sensitive working condition. (ERA citation 10:042554)