首页> 美国政府科技报告 >Evaluation Report on CCTF CORE-I REFLOOD TEST Cl-4 (Run 13) and Cl-15 (Run 24). Investigation of the Refill Simulation and the Nitrogen Injection Effects
【24h】

Evaluation Report on CCTF CORE-I REFLOOD TEST Cl-4 (Run 13) and Cl-15 (Run 24). Investigation of the Refill Simulation and the Nitrogen Injection Effects

机译:CCTF CORE-I REFLOOD TEsT Cl-4(运行13)和Cl-15(运行24)的评估报告。再填充模拟和注氮效果的研究

获取原文

摘要

The tests Cl-4 and Cl-15 were performed with the Cylindrical Core Test Facility (CCTF) to investigate the effects of the depressurization process to simulate the refill phase, and the effects of the nitrogen to be injected after the end of the accumulator injection on the thermo-hydraulic behavior in the core and primary loop system during refill and reflood phases. In these tests, after the lower plenum was filled to 0.9m level with saturated water at 0.6 MPa, the accumulator water was injected into three intact cold legs in the depressurization period from 0.6 MPa to 0.2 MPa. The water in the lower plenum voided during the depressurization and the significant steam condensation occurred in or near the intact cold legs. The condensation caused high steam flow rate in the intact loops and the lower plenum flashing resulted in suppressed core water accumulation. The slightly lower core heat transfer coefficient due to the less core water caused the higher turnaround temperature and the longer quench time than those of the normal reflood test without the depressurization process. The nitrogen injection followed the accumulator injection was allowed in the test Cl-15. However, significant effects of the nitrogen injection was not observed. (Atomindex citation 15:059466)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号