首页> 美国政府科技报告 >Control and Operation Cost Optimization of the HISS Cryogenic System
【24h】

Control and Operation Cost Optimization of the HISS Cryogenic System

机译:HIss低温系统的控制和运行成本优化

获取原文

摘要

The Heavy Ion Spectrometer System (HISS) relies upon superconducting coils of cryostable design to provide a maximum particle bending field of 3 tesla. A previous paper describes the cryogenic facility including helium refrigeration and gas management. This paper discusses a control strategy which has allowed full time unattended operation, along with significant nitrogen and power cost reductions. Reduction of liquid nitrogen consumption has been accomplished by making use of the sensible heat available in the cold exhaust gas. Measured nitrogen throughput agrees with calculations for sensible heat utilization of zero to 70%. Calculated consumption saving over this range is 40 liters per hour for conductive losses to the supports only. The measured throughput differential for the total system is higher. (ERA citation 08:056267)